  • The variability of the photoplethysmographic signal--a potential method for the evaluation of the autonomic nervous system.

    abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/19/1/008

    authors: Nitzan M,Babchenko A,Khanokh B,Landau D

    更新日期:1998-02-01 00:00:00

  • Value of simulated body surface potential maps as templates in localizing sites of ectopic activation for radiofrequency ablation.

    abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/4/010

    authors: Hren R,Horácek BM

    更新日期:1997-11-01 00:00:00

  • A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry.

    abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/3/008

    authors: Steel SA,Swann P,Langley G,Langton CM

    更新日期:1997-08-01 00:00:00

  • Detection of animal tissue thickness using simple vertical electric sounding (VES).

    abstract::Tetrapolar linear arrays are commonly used in geophysics to explore the vertical distribution of resistivity values in a geological section of a specific point on the earth. This technique, known as vertical electric sounding (VES), uses different electrode configurations. For our experiments, we utilized its more pop...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/1/007

    authors: Gonzalez CA,offniga O,Padilla LE

    更新日期:1997-02-01 00:00:00

  • EIT data noise evaluation in the clinical environment.

    abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/006

    authors: Meeson S,Blott BH,Killingback AL

    更新日期:1996-11-01 00:00:00

  • EITS changes following oleic acid induced lung water.

    abstract::We present the results of using electrical impedance tomographic spectroscopy (EITS) to follow the changes in lung water induced by oleic acid. Measurements were made on three goats before and after the injection of oleic acid. In addition to the EITs measurements, lung water was also measured using a double-indicator...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/016

    authors: Brown BH,Flewelling R,Griffiths H,Harris ND,Leathard AD,Lu L,Morice AH,Neufeld GR,Nopp P,Wang W

    更新日期:1996-11-01 00:00:00

  • Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

    abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/026

    authors: Nopp P,Zhao TX,Brown BH,Wang W

    更新日期:1996-11-01 00:00:00

  • Validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake.

    abstract::The purpose of this study was to determine the validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake (VO2max). Fifty-two healthy volunteers had their VO2max determined during a maximal treadmill run. They also performed a timed 5 km cycle ergometer ride. The resistance setting ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1088/0967-3334/17/4/009

    authors: Buono MJ,Borin TL,Sjoholm NT,Hodgdon JA

    更新日期:1996-11-01 00:00:00

  • The effect of fracture and fracture fixation on ultrasonic velocity and attenuation.

    abstract::Measurement of the velocity of propagation and attenuation of ultrasound (200 kHz) is believed to be a useful non-invasive technique for assessing the mechanical properties of bone. A new method for the determination of ultrasound velocity and attenuation of longitudinal waves in cortical bone was used in vivo and in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/17/3/006

    authors: Saulgozis J,Pontaga I,Lowet G,Van der Perre G

    更新日期:1996-08-01 00:00:00

  • The origin of skin-stretch-caused motion artifacts under electrodes.

    abstract::The outside of the skin of the forearm is typically 15 mV more negative than the inside. Stretching the skin causes a reduction in the magnitude of this skin potential V, which we observe as a motion artifact delta V. We seek to determine the origin of this motion artifact by successively stripping 12 layers of the sk...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/2/003

    authors: de Talhouet H,Webster JG

    更新日期:1996-05-01 00:00:00

  • A multifrequency multichannel electrical impedance data acquisition system for body fluid shift monitoring.

    abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/4/003

    authors: Lozano A,Rosell J,Pallás-Areny R

    更新日期:1995-11-01 00:00:00

  • 3D reconstruction in electrical impedance imaging using a direct sensitivity matrix approach.

    abstract::This paper represents a reconstruction algorithm using a direct sensitivity matrix (DSM) approach for fast 3D image reconstruction in electrical impedance imaging. The boundary element method (BEM) is used in the construction of this matrix. The first images of a conductivity perturbation inside a sphere are reconstru...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/012

    authors: Morucci JP,Granié M,Lei M,Chabert M,Marsili PM

    更新日期:1995-08-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography.

    abstract::The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventiona...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/009

    authors: Boone KG,Holder DS

    更新日期:1995-08-01 00:00:00

  • A measurement of pulmonary blood volume increase during systole in humans.

    abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/15/4/010

    authors: Nitzan M,Mahler Y,Schechter D,Yaffe S,Bocher M,Chisin R

    更新日期:1994-11-01 00:00:00

  • Performance measurements of an infrared digital scanning laser ophthalmoscope.

    abstract::Direct digital acquisition of images using a scanning laser ophthalmoscope (SLO) offers several advantages over the conventional fundus camera; in particular, the ability to produce tomographic images using a confocal aperture. This note describes measurements of the performance of an SLO. Spatial resolution, measured...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/3/010

    authors: Manivannan A,Sharp PF,Forrester JV

    更新日期:1994-08-01 00:00:00

  • Multi-frequency imaging and modelling of respiratory related electrical impedance changes.

    abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/001

    authors: Brown BH,Barber DC,Wang W,Lu L,Leathard AD,Smallwood RH,Hampshire AR,Mackay R,Hatzigalanis K

    更新日期:1994-05-01 00:00:00

  • A method of reducing the error caused by boundary shape and electrode positions in electrical impedance tomography.

    abstract::This paper describes a method of reducing the influence of the data error caused by non-ideal boundary shape and electrode placement on reconstructed images. A data calibration and a modified Newton-Raphson reconstruction are combined in the method to ensure rapid convergence and small reconstruction error. The method...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/022

    authors: Li J

    更新日期:1994-05-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • Comparison of macro- and micro-lightguide spectrophotometric measurements of microvascular haemoglobin oxygenation in the tuberculin reaction in normal human skin.

    abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2/002

    authors: Newton DJ,Harrison DK,Delaney CJ,Beck JS,McCollum PT

    更新日期:1994-05-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance.

    abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4/007

    authors: Netz J,Forner E,Haagemann S

    更新日期:1993-11-01 00:00:00

  • Localization of sources of brain alpha/theta/delta activity and the influence of the mode of spontaneous mentation.

    abstract::A method is described that accounts for multichannel brain field data (EEG) epochs, after transformation into the frequency domain, by a single oscillating dipole source in terms of phase angles. The method produces a potential distribution for each frequency point ('FFT dipole approximation'). These maps can be subje...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4a/004

    authors: Michel CM,Henggeler B,Brandeis D,Lehmann D

    更新日期:1993-11-01 00:00:00

  • Auditory magnetic fields in cochlear-implant patients.

    abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/14/4a/014

    authors: Pelizzone M

    更新日期:1993-11-01 00:00:00

  • Fractal analysis of foetal heart rate variability.

    abstract::Current methods for analysing foetal heart rate (FHR) patterns have yet to meet their full potential in the recognition of hypoxia in the foetus. Following the recent suggestion that fractal analysis can be applied to FHR recordings, the current paper describes a method for distinguishing two simultaneous fractal dime...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/3/009

    authors: Gough NA

    更新日期:1993-08-01 00:00:00

  • Within-breath measurement of respiratory impedance.

    abstract::The measurement of the complex respiratory impedance at a high temporal resolution is described. The measurement of impedance is correlated with the breathing cycle using electrical transthoracic impedance. This allows the determination of the complex impedance at any fixed point in the respiratory cycle, which result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/3/019

    authors: van der Putten WJ,MacLeod D,Prichard JS

    更新日期:1993-08-01 00:00:00

  • Triple-frequency method for measuring blood impedance.

    abstract::A method was developed for simultaneously measuring plasma resistance, cell interior resistance and cell membrane capacitance of blood. A three-element circuit model for simulating the impedance of blood was evaluated by comparing measured and calculated impedance frequency curves and was found feasible. The values of...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/2/006

    authors: Zhao TX,Jacobson B,Ribbe T

    更新日期:1993-05-01 00:00:00

  • A comparison of methods for estimating left ventricular volumes from radionuclide ventriculography.

    abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/1/004

    authors: Thorley PJ,Sheard KL,Rees MR

    更新日期:1993-02-01 00:00:00

308 条记录 8/8 页 « 12345678 »